• Home
  • About us
  • Products
  • DOWNLOADS
  • Contact us
Linkedin Instagram Facebook
All departments
  • Switching Low Voltage Products
  • Enclosures
  • Cables
  • Earthing Materials and Connectors
  • Terminals
  • Transformers
  • Explosion Proof Products
+90 553 122 89 38
Menu Categories
  • Home
  • About us
  • Products
  • DOWNLOADS
  • Contact us
  • Copper Busbar & Products
  • Switching Low Voltage Products
    • Contactor
    • Circuit Breaker MCB
    • Circuit Breaker MCCB
    • Automatic Transfer Changerover Switch ATS
    • Fuses
  • Automation
  • Drives
  • Industrial Automation
  • HVAC
  • Energy Efficiency
  • Water Solutions
  • Earthing Materials and Connectors
  • Pumps
  • Cables
  • Refrigeration
  • Enclosures
    • Metal Enclosure
    • Plastic Enclosures
  • Elevators
  • Explosion Proof Products
  • Industrial Sockets
  • Terminals
    • Distribution Units
    • Terminals & Bars
    • Splicing Terminals
    • Terminal Blocks
    • Terminal Strips
  • Transformers
  • Current Transformers
  • Temperature Sensor
Linkedin Instagram Facebook
Home  /  Terminals  /  Terminals & Bars  / 

CHINT NB3L-40 Residual Current Operated Circuit Breaker

CHINT NB3L-40 Residual Current Operated Circuit Breaker

Add to wishlist
Category: Terminals & Bars
Brand: CHINT
Share: Facebook Twitter Tumblr Linkedin Whatsapp

You may also like

  • Siemens GIB161.1U Non-spring Return 310 lb-in 24 Vac

    Siemens GIB161.1U Non-spring Return 310 lb-in 24 Vac

  • 830674 / WML 6 (13X13)R YE Phoenix Contact Wire-wrap label, Roll, yellow, unmarked, can be labeled with: THERMOMARK E.300 (D)/600 (D)

    830674 / WML 6 (13X13)R YE Phoenix Contact Wire-wrap label, Roll, yellow, unmarked, can be labeled with: THERMOMARK E.300 (D)/600 (D)

  • 1SDA072385R1MP / E2.2N 2000 Ekip Touch LSI 3p WMP +Ekip Measuring Ölçüm Modülü ABB HREE-POLE WITH SOLID-STATE

    1SDA072385R1MP / E2.2N 2000 Ekip Touch LSI 3p WMP +Ekip Measuring Ölçüm Modülü ABB HREE-POLE WITH SOLID-STATE

  • Turbine Flow Meter - Explosion-proof Type

    Turbine Flow Meter - Explosion-proof Type

  • Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Override Setpoint - Sensor Base not Included SXWSC3XSELXX

    Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Override Setpoint - Sensor Base not Included SXWSC3XSELXX

  • Liquid level control box

    Liquid level control box

Description
Shipping & delivery

CHINT NB3L-40 Residual Current Operated Circuit Breaker,

with over-current protection (Magnetic) combines residual current protection and over-current protection in one compact unit,
offering reliable performance in low-voltage electrical systems.
Designe for 400/415 V AC networks, it provides 10 kA breaking capacity, precision tripping through magnetic release technology,
and flexible configurations for different load types (B, C, and D curves).
The NB3L-40 is ideal for industrial and commercial installations requiring dependable safety and performance.

  • Function: Combined overload, short-circuit, and residual current protection
  • Standards Compliance: IEC/EN 61009-1
  • Rated Voltage (Ue): 400/415 V AC
  • Rated Current (In): 6 A, 10 A, 13 A, 16 A, 20 A, 25 A, 32 A, 40 A
  • Poles: 3P+N
  • Rated Frequency: 50/60 Hz
  • Tripping Curves:
    • B Curve: For resistive circuits and long cables
    • C Curve: For mixed resistive/inductive loads
    • D Curve: For high-inductive loads with high inrush current
  • Rated Residual Operating Current (IΔn): 30 mA, 100 mA, 300 mA
  • Leakage Type: Type A and AC (pulsed DC and AC sensitivity)
  • Rated Short-circuit Capacity (Icn): 10 kA
  • Rated Residual Making/Breaking Capacity (IΔm): 6,000 A
  • Insulation Voltage (Ui): 500 V
  • Rated Impulse Withstand Voltage (Uimp): 4 kV
  • Dielectric Test Voltage: 2 kV for 1 minute
  • Mechanical Life: 10,000 operations
  • Electrical Life: 4,000 operations
  • Break Time Under IΔn: ≤ 0.1 s
  • Ambient Operating Temperature: –5 °C to +40 °C (average ≤ 35 °C)
  • Storage Temperature: –25 °C to +70 °C
  • Temperature Derating Reference: 30 °C; coefficient reduces to 0.80 at 70 °C
  • Pollution Degree: 2
  • Protection Degree: IP20
  • Mounting Type: DIN rail EN 60715 (35 mm)
  • Connection Type: Cable, U-type busbar, or pin-type busbar (top/bottom)
  • Terminal Capacity:
    • Cable: up to 25 mm² (AWG 18–3)
    • Busbar: 10 mm² (AWG 18–8)
  • Tightening Torque: 2 N·m (≈ 18 in·lbs)
  • Certifications: CE, CB, KEMA, RoHS

Related products

1SFL487102R1300 / AF190-40-00-13 ABB contactor with Main Circuit Bars, controlling motors up to 90 kW / 400 V AC (AC-3) / and switching power circuits
Read more Quick View
Temperature Sensor, Terminals & Bars

1SFL487102R1300 / AF190-40-00-13 ABB contactor with Main Circuit Bars, controlling motors up to 90 kW / 400 V AC (AC-3) / and switching power circuits

Schneider STD Series temperature sensor STD300-300 duct 0-100 °C 006920141
Read more Quick View
Terminals & Bars

Schneider STD Series temperature sensor STD300-300 duct 0-100 °C 006920141

Schneider Replaceable sensor SpaceLogic SLX humidity gen 2  1% accuracy with NIST calibration certificate SLXRHS1N
Read more Quick View
Terminals & Bars

Schneider Replaceable sensor SpaceLogic SLX humidity gen 2 1% accuracy with NIST calibration certificate SLXRHS1N

Schneider SLA SpaceLogic Series Temperature Sensor Room Resistive 10K T3 Optimum White Housing SLAWTXX
Read more Quick View
Terminals & Bars

Schneider SLA SpaceLogic Series Temperature Sensor Room Resistive 10K T3 Optimum White Housing SLAWTXX

Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Blank - Sensor Base not inluded SXWSCBXSELXX
Read more Quick View
Terminals & Bars

Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Blank – Sensor Base not inluded SXWSCBXSELXX

Copper Bar
Read more Quick View
Terminals & Bars

Copper Bar

CHINT NB1-63 Miniature Circuit...

CHINT NB4LE-AFD Residual Curre...

We are at your Service 24/7 ... Whatsapp : +90 553 122 89 38

HS Grup is a trusted supplier of industrial electrical materials and switchgears and automation systems, offering reliable and innovative solutions for a wide range of applications. With a strong focus on quality, safety, and customer satisfaction

Useful Links

  • Home
  • About us
  • Products
  • DOWNLOADS
  • Contact us

Products

  • Current Transformers
  • Metal Enclosures
  • Terminal Block

Contact Us

Turkey Headquarter:
Email = info@hsgrup.com.tr
Phone = +90 553 122 89 38
Mon – Fri 9:00 AM to 6:30 PM SUNDAY – Closed
Address: A: HALİL RIFAT PAŞA MAH. YÜZER HAVUZ SK. PERPA TİC MER B BLOK NO: 543 ŞİŞLİ / İSTANBUL

China Office:
HUANGGANG HS GRUP ELEKTRIK CO LTD
Address: Room 4, 7F, Building 2, Chibi Yuan,4 Chibi Lake Road, Huangzhou District, Huanggang City, Hubei Province

Facebook Instagram Linkedin

Copyright © 2025 HS Group  All rights reserved.

WhatsApp us