• Home
  • About us
  • Products
  • DOWNLOADS
  • References
  • Partners
  • Contact us
Linkedin Instagram Facebook
All departments
  • Switching Low Voltage Products
  • Enclosures
  • Cables
  • Earthing Materials and Connectors
  • Terminals
  • Current Transformers
  • Explosion Proof Products
+90 553 122 89 38
Menu Categories
  • Home
  • About us
  • Products
  • DOWNLOADS
  • References
  • Partners
  • Contact us
  • Automation
  • Industrial Sockets
  • Copper Busbar & Products
  • Enclosures
  • Switching Low Voltage Products
    • Automatic Transfer Changerover Switch ATS
    • Contactor
    • Circuit Breaker MCCB
  • Core Balance Current Transformer
  • Distribution Units
  • Metal Enclosure
  • Plastic Enclosure
  • Terminals & Bars
  • Temperature Sensor
  • Terminal Blocks
Linkedin Instagram Facebook
Home  /  Terminals & Bars  / 

CHINT NL210 Residual Current Operated Circuit Breaker

CHINT NL210 Residual Current Operated Circuit Breaker

Add to wishlist
Category: Terminals & Bars
Brand: CHINT
Share: Facebook Twitter Tumblr Linkedin Whatsapp

You may also like

  • 2905636 / MINI MCR-2-V8-PB-DP Phoenix Contact Eight MINI Analog Pro signal conditioners and measuring transducers are quickly and easily integrated

    2905636 / MINI MCR-2-V8-PB-DP Phoenix Contact Eight MINI Analog Pro signal conditioners and measuring transducers are quickly and easily integrated

  • AUTONICS SPB-A015-05

    AUTONICS SPB-A015-05

  • Belimo 22ADP-566L Differential Pressure Sensor Air, 0...28 inch WC [0...7000 Pa], BACnet, 0...5 V, 0...10 V, LCD

    Belimo 22ADP-566L Differential Pressure Sensor Air, 0...28 inch WC [0...7000 Pa], BACnet, 0...5 V, 0...10 V, LCD

  • 5800 8 ports protocol converter for RS232/485/422 and TCP/IP

    5800 8 ports protocol converter for RS232/485/422 and TCP/IP

  • WEIDMULLER S2C 2.5 PE PE terminal 2674560000

    WEIDMULLER S2C 2.5 PE PE terminal 2674560000

  • 1SDA066798R1 / A2N 250 TMF 250-2500 4p F F ABB C.BREAKER FORMULA A2N 250 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 250-2500 A

    1SDA066798R1 / A2N 250 TMF 250-2500 4p F F ABB C.BREAKER FORMULA A2N 250 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMF R 250-2500 A

Description
Shipping & delivery

CHINT NL210 Residual Current Operated Circuit Breaker,

without over-current protection (RCCB) is designe for protection against earth fault currents and fire hazards in residential,
commercial, and industrial installations. As a Type B RCCB, it detects AC, pulsating DC,
and smooth DC residual currents up to 1000Hz, ensuring maximum safety for modern electrical systems.
Compliant with IEC/EN 62423 and IEC/EN 61008-1, the NL210 provides instantaneous tripping,
sensitivity options of 30mA–300mA, and a 10kA short-circuit rating, ensuring dependable protection without over-current functionality.

  • Function:
    • Controls electrical circuits
    • Protects people from indirect contact and provides additional protection from direct contact
    • Prevents fire hazards caused by insulation faults
  • Type: Type B – detects AC, pulsating DC, and smooth DC residual currents up to 1000Hz
  • Rated Current (In): 25A, 40A, 63A
  • Number of Poles: 2P, 4P
  • Rated Voltage (Ue):
    • 2P: 230/240V AC
    • 4P: 400/415V AC
  • Rated Sensitivity (IΔn): 30mA, 100mA, 300mA
  • Tripping Mode: Instantaneous (no time delay)
  • Rated Insulation Voltage (Ui): 500V
  • Rated Residual Making & Breaking Capacity (IΔm):
    • 500A for 25A/40A models
    • 630A for 63A model
  • Short-circuit Current (Inc = IΔc): 10kA
  • SCPD Fuse Rating: 10,000A
  • Tripping Time under IΔn: ≤0.1s
  • Rated Frequency: 50Hz
  • Rated Impulse Withstand Voltage (Uimp): 4kV
  • Dielectric Strength: 2kV for 1 minute
  • Pollution Degree: 2
  • Electrical Life: 4,000 operations
  • Mechanical Life: 10,000 operations
  • Operating Temperature: −25°C to +40°C
  • Storage Temperature: −25°C to +70°C
  • Protection Degree: IP20
  • Terminal Connection Type: Cable, U-type busbar, or pin-type busbar
  • Terminal Size:
    • Cable: 25mm² (In ≤ 40A), 35mm² (In = 63A)
    • Busbar: 10–16mm²
  • Tightening Torque: 2.5 N·m (22 in-lbs)
  • Mounting: DIN rail EN 60715 (35mm), with fast clip device
  • Connection: From top or bottom
  • Dimensions (mm):
    • 2P: 54(W) × 91(H) × 49.5(D)
    • 4P: 72(W) × 91(H) × 49.5(D)
  • Approvals: CE, KEMA, VDE, RoHS, REACH
  • Accessories: AX-5 auxiliary contact, TC-1 terminal cover

Related products

Schneider SXWS SmartX temperature sensor  LCD display setpoint override cover included SXWSATXXXSLX
Read more Quick View
Terminals & Bars

Schneider SXWS SmartX temperature sensor LCD display setpoint override cover included SXWSATXXXSLX

Schneider SLO320 Outdoor Electronic Light Transmitter 006920640
Read more Quick View
Terminals & Bars

Schneider SLO320 Outdoor Electronic Light Transmitter 006920640

Schneider SXWS SmartX Temperature Sensor Resistive 10K Type 3 Thermistor Blank with Matte White Cover SLASXXX
Read more Quick View
Terminals & Bars

Schneider SXWS SmartX Temperature Sensor Resistive 10K Type 3 Thermistor Blank with Matte White Cover SLASXXX

Schneider Replaceable sensor SpaceLogic SLX humidity gen 2  1% accuracy with NIST calibration certificate SLXRHS1N
Read more Quick View
Terminals & Bars

Schneider Replaceable sensor SpaceLogic SLX humidity gen 2 1% accuracy with NIST calibration certificate SLXRHS1N

HS Group - Electrical Automation Products
Read more Quick View
Terminals & Bars

Schneider Temp Sensor STX520-200 Immersion 2 m cable (6.56 ft) Andover Continuum 5123320000

Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Blank - Sensor Base not inluded SXWSCBXSELXX
Read more Quick View
Terminals & Bars

Schneider SXWS Cover Plate for Sensor Base for SmartX IP Controllers Blank – Sensor Base not inluded SXWSCBXSELXX

CHINT NH4 Switch Disconnector

CHINT NB8 -63 Miniature Circui...

We are at your Service 24/7 ... Whatsapp : +90 553 122 89 38

HS Grup is a trusted supplier of industrial electrical materials and switchgears and automation systems, offering reliable and innovative solutions for a wide range of applications. With a strong focus on quality, safety, and customer satisfaction

Useful Links

  • Home
  • About us
  • Products
  • DOWNLOADS
  • References
  • Partners
  • Contact us

Products

  • Current Transformers
  • Metal Enclosures
  • Terminal Block

Contact Us

Turkey Headquarter:
Email = info@hsgrup.com.tr
Phone = +90 553 122 89 38
Mon – Fri 9:00 AM to 6:30 PM SUNDAY – Closed
Address: A: HALİL RIFAT PAŞA MAH. YÜZER HAVUZ SK. PERPA TİC MER B BLOK NO: 543 ŞİŞLİ / İSTANBUL

China Office:
HUANGGANG HS GRUP ELEKTRIK CO LTD
Address: Room 4, 7F, Building 2, Chibi Yuan,4 Chibi Lake Road, Huangzhou District, Huanggang City, Hubei Province

Facebook Instagram Linkedin

Copyright © 2025 HS Group  All rights reserved.

WhatsApp us